Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.789
Filtrar
1.
Res Theory Nurs Pract ; 38(2): 252-269, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38663969

RESUMO

Purpose: The study aimed to examine the effect of a child-friendly design on the pain and anxiety levels during blood draw in children aged 1-3 years and the satisfaction levels of their parents toward the environment in which they receive health care services. Methods: The nonrandomized study was conducted with 158 children aged 1-3 years and their parents. Data were obtained with the "Personal Information Form," "Face, Legs, Activity, Cry, Consolability (FLACC) Pain Scale," "Visual Analog Scale (VAS) Anxiety Scale," and "Parental Satisfaction Scale-VAS." Data were collected from the control group before the design and from the intervention group after the design. Results: During the blood draw, the VAS Anxiety score of the children in the intervention group was 3.17 ± 1.44 and that of the control group was 7.00 ± 2.51 (t = 246.500, p < .001). The FLACC score was 3.94 ± 1.65 in the intervention group and 7.32 ± 2.51 in the control group (t = 915.000, p < .001). The mean satisfaction scores of the parents in the intervention group for the environment where they received health care were 10.00 ± 0.00, and those of the parents in the control group were 4.85 ± 1.68 (test = -11.561, p < .001). Conclusion: The child-friendly design effectively reduced children's pain and anxiety levels during blood draws and increased parents' satisfaction with the environment in which health care was received. Practical Implications: Implementing a child-friendly design in blood collection units is recommended to alleviate the pain and anxiety associated with children's blood draws, thereby enhancing parental satisfaction with the care provided.


Assuntos
Ansiedade , Humanos , Pré-Escolar , Masculino , Ansiedade/prevenção & controle , Feminino , Lactente , Pais/psicologia , Manejo da Dor/métodos , Medição da Dor , Coleta de Amostras Sanguíneas/psicologia , Dor/psicologia , Dor/prevenção & controle
2.
Biochem Med (Zagreb) ; 34(2): 020704, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38665870

RESUMO

Introduction: Clinical laboratories should guarantee sample stability in specific storage conditions for further analysis. The aim of this study is to evaluate the stability of plasma samples under refrigeration for 29 common biochemical analytes usually ordered within an emergency context, in order to determine the maximum allowable period for conducting add-on testing. Materials and methods: A total of 20 patient samples were collected in lithium heparin tubes without gel separator. All analyses were performed using Alinity systems (Abbott Laboratories, Abbott Park, USA) and samples were stored at 2-8 °C. Measurements were conducted in primary plasma tubes at specific time points up to 48 hours, with an additional stability study in plasma aliquots extending the time storage up to 96 hours. The stability limit was estimated considering the total limit of change criteria. Results: Of the 29 studied parameters, 24 demonstrated stabilities within a 48-hour storage period in primary plasma tubes. However, five analytes: aspartate aminotransferase, glucose, lactate dehydrogenase, inorganic phosphate and potassium evidenced instability at different time points (7.9 hours, 2.7 hours, 2.9 hours, 6.2 hours and 4.7 hours, respectively). The stability study in plasma aliquots showed that all parameters remained stable for 96 hours, except lactate dehydrogenase, with a stability limit of 63 hours. Conclusions: A reduced stability of primary plasma samples was observed for five common biochemical analytes ordered in an emergency context. To ensure the quality of add-on testing for these samples, plasma aliquots provide stability for a longer period.


Assuntos
Coleta de Amostras Sanguíneas , Humanos , Coleta de Amostras Sanguíneas/normas , Análise Química do Sangue/normas , Controle de Qualidade , Garantia da Qualidade dos Cuidados de Saúde , Aspartato Aminotransferases/sangue , L-Lactato Desidrogenase/sangue , Plasma/química , Manejo de Espécimes/normas
3.
RMD Open ; 10(2)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38642927

RESUMO

BACKGROUND: During the COVID-19 pandemic, we developed a digital research platform to longitudinally investigate COVID-19-related outcomes in patients with rheumatic diseases and healthy controls. We used home finger-prick testing in order to collect serum samples remotely and increase the overall efficiency of the platform. The aim of the present study was to evaluate the success rate of the finger prick and patients' perspective towards the finger prick. METHODS: Serum samples were collected up to five times during follow-up, either via a venepuncture at the research institute or a finger prick from participants' home. Participants were asked to complete a digital evaluation questionnaire of the finger prick after their attempts. RESULTS: A total of 2135 patients and 899 controls performed at least one finger prick and were included in this study. The first finger prick was successfully done by 92% (95% CI: 90% to 93%) of patients, 94% (95% CI: 92% to 95%) of controls, 93% (95% CI: 92% to 94%) of all participants aged ≤70 years and 89% (95% CI: 86% to 92%) of all participants aged >70 years. Sex did not impact these success rates. Repeated failure occurred in 11/439 (0.8%) patients and 4/712 (0.6%) controls. Both patients and controls were less willing to perform a finger prick for individual healthcare compared with scientific research. CONCLUSION: The vast majority of participants, among which elderly and patients with rheumatic diseases, were able to successfully draw the required amount of blood for serological analyses. This shows that finger-prick testing is suitable for a high-throughput implementation to monitor patients remotely.


Assuntos
COVID-19 , Doenças Reumáticas , Reumatologia , Idoso , Humanos , Pandemias , Estudos de Viabilidade , Coleta de Amostras Sanguíneas , COVID-19/diagnóstico , COVID-19/epidemiologia , Doenças Reumáticas/diagnóstico
4.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 32(2): 577-582, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38660869

RESUMO

OBJECTIVE: To explore the optimal storage condition and time of umbilical cord blood from collection to preparation. METHODS: Collect cord blood samples from 30 healthy newborns, with each new born's umbilical cord blood was divided into two parts on average. One part was stored in cold storage (4 ℃) and the other was stored at room temperature (20-24 ℃). Samples were taken at 24, 36, 48, 60 and 72 h, respectively, total nucleated cells (TNC) count and TNC viability was analyzed. Flow cytometry was used to detect the ratio of viable CD34+ cells to viable CD45+ cells and viability of CD34+ cells, and colony-forming unit-granulocyte-macrophage (CFU-GM) count was performed by hematopoietic progenitor cell colony culture. The change trend of each index over time was observed, and the differences in each index was compared between cold storage and room temperature storage under the same storage time. RESULTS: The TNC count (r 4 ℃=-0.9588, r 20-24 ℃=-0.9790), TNC viability (r 4 ℃=-0.9941, r 20-24 ℃=-0.9970), CD34+ cells viability (r 4 ℃=-0.9932, r 20-24 ℃=-0.9828) of cord blood stored in cold storage (4 ℃) and room temperature storage (20-24 ℃) showed a consistent downward trend with the prolongation of storage time. The percentage of viable CD34+ cells (r 4 ℃=0.9169, r 20-24 ℃=0.7470) and CFU-GM count (r 4 ℃=-0.2537, r 20-24 ℃=-0.8098) did not show consistent trends. When the storage time was the same, the TNC count, TNC viability, CD34+ cells viability and CFU-GM count of cord blood stored in cold storage were higher than those stored at room temperature. Under the same storage time (24, 36, 48, 60 or 72 h), TNC viability in room temperature storage was significantly lower than that in cold storage (P <0.001), but TNC count, percentage of viable CD34+ cells and CFU-GM count were not significantly different between room temperature storage and cold storage. When stored at room temperature for 24 h and 36 h, the viability of CD34+ cells was significantly lower than that in cold storage (P <0.001, P <0.01), when the storage time for 48, 60 and 72 h, there was no significant difference in the CD34+ cells viability between room temperature storage and cold storage. CONCLUSION: It is recommended that cord blood be stored in cold storage (4 ℃) from collection to preparation, and processed as soon as possible.


Assuntos
Antígenos CD34 , Preservação de Sangue , Sangue Fetal , Humanos , Sangue Fetal/citologia , Recém-Nascido , Fatores de Tempo , Citometria de Fluxo , Células-Tronco Hematopoéticas/citologia , Sobrevivência Celular , Temperatura , Coleta de Amostras Sanguíneas
5.
Sci Rep ; 14(1): 8628, 2024 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622175

RESUMO

Peripheral blood RNA profiling, which can reveal systemic changes in gene expression and immune responses to disease onset and progression, is a powerful tool for diagnosis and biomarker discovery. This technique usually requires high quality RNA, which is only obtainable from fresh blood, or frozen blood that has been collected in special RNA-stabilisation systems. The current study aimed to develop a novel protocol to extract high quality RNA from frozen blood that had been collected in the conventional EDTA tubes. We determined that thawing EDTA blood in the presence of cell lysis/RNA stabilisation buffers (Paxgene or Nucleospin) significantly improved RNA quality (RIN) from below 5 to above 7, which to date has not been shown possible. The EDTA-Nucleospin protocol resulted in 5 times higher yield than the EDTA-Paxgene-PreAnalytix method. The average RIN and mRNA expression levels of five different genes including 18 s, ACTB, MCP1, TNFa and TXNIP using this protocol were also indifferent to those from Paxgene blood, suggesting similar RNA quality and blood transcriptome. Moreover, the protocol allows DNA to be extracted simultaneously. In conclusion, we have developed a practical and efficient protocol to extract high quality, high yield RNA from frozen EDTA blood.


Assuntos
Perfilação da Expressão Gênica , RNA , RNA/genética , Ácido Edético/farmacologia , Perfilação da Expressão Gênica/métodos , Coleta de Amostras Sanguíneas/métodos , Transcriptoma
6.
Br J Nurs ; 33(7): S36-S42, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38578933

RESUMO

HIGHLIGHTS: Patient comfort during peripheral intravenous (PIV) insertion and specimen collection was increased. The authors extended the contingency plan implemented for PICC insertion to include PIV insertion and specimen collection. The authors met their goals by using quality improvement methodology. Prioritizing patient comfort often requires institutional culture change. BACKGROUND: Needle procedures can cause pain and distress, especially in pediatric patients.1 Retrospective data collected at a freestanding pediatric facility revealed that approximately 30% of pediatric patients were not demonstrating sufficient levels of comfort during peripheral intravenous (PIV) catheter insertion and specimen collection (lab draws) even after successful implementation of comfort measures by the vascular access team (VAT) in an adjacent procedure (eg peripherally inserted central catheter placement). The current quality improvement project was implemented to support adaptation and expansion of previous lessons learned to PIVs and lab draws specifically. DESIGN AND METHODS: The VAT used the Pediatric Sedation State Scale,2 a standardized assessment tool integrated into the electronic medical record, to assess procedural comfort during PIVs and lab draws from February 2021 through April 2023. A total of 24 134 patients aged 0 to 18 years were included in the data collection. Interventions were delivered concurrently and included (1) reeducation/ongoing support for implementation of the Comfort Promise3 measures, (2) the creation and implementation of advanced comfort options, and (3) culture change. AIMS AND OBJECTIVES: The goal of the interventions was to improve the percentage of pediatric patients achieving adequate levels of comfort beginning at 68% in year 1 to 90% in year 2. RESULTS: From February 2021 to April 2023, the VAT team was able to improve procedural comfort scores from 68% to 90% of pediatric patients with adequate comfort for lab draws and/or PIV insertions. CONCLUSIONS: While standard comfort measures are a good first step in pain management during needle procedures, they are not sufficient for every pediatric patient. Nitrous, sedation, and the use of anxiolytics and analgesics can play an important role in reducing pain and anxiety during needle procedures and should be considered for patients not achieving adequate levels of comfort with standard comfort measures.


Assuntos
Cateterismo Periférico , Conforto do Paciente , Criança , Humanos , Estudos Retrospectivos , Melhoria de Qualidade , Coleta de Amostras Sanguíneas , Cateterismo Periférico/métodos , Dor
7.
Actual. Sida Infectol. (En linea) ; 32(114): 16-25, 20240000. tab
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1551795

RESUMO

Introducción. El problema de la contaminación de los hemocultivos es muy frecuente en establecimientos de atención hospitalaria, da lugar a la administración de antibióticos innecesarios y prolonga la hospitalización. Objetivo principal. Aplicar un bundle para reducir la proporción de contaminación de hemocultivos. Objetivo secundario. Realizar una encuesta anónima para detectar oportunidades de mejora en la técnica de extracción de hemocultivos. Metodología. Diseño del estudio: Estudio cuasi experimental que evaluó la proporción de contaminación de hemocultivos antes y después de implementar un bundle propio. Se determinó la proporción basal de contaminación de hemocultivos (ene-jul 2022), se realizó la intervención (agosto 2022) y se estableció la proporción de contaminación post intervención (sep.-abril 2023). Intervención: Se analizó la estructura, procedimiento y conocimiento del personal mediante una encuesta propia para detectar áreas de mejora. Se capacitó, a los técnicos de laboratorio, sobre el procedimiento de la toma de muestra mediante una simulación utilizando un brazo artificial. Se diseñó un bundle de seis medidas, se adaptó el procedimiento de toma de hemocultivo y se capacitó al personal. Análisis estadístico. Se analizó la proporción de hemocultivos contaminados entre los periodos pre y post utilizando Chi2 y la relación entre la proporción del periodo pre y post vs la literatura (3.00% contaminación aceptable) utilizando test Z para una proporción. Se consideró un p<0.05 como estadísticamente significativa. Se utilizo el software Stata 8. Resultados. Durante el estudio se analizaron un total de 3,965 hemocultivos. De estos, 1,978 corresponden al periodo pre-intervención y 1,987 corresponden al periodo post intervención. Durante la pre-intervención se detectaron 61 hemocultivos contaminados (3.08% vs 3.00% bibliografía, p:0.5866) mientras que en la etapa post intervención fue de 30 hemocultivos contaminados (1.51% vs 3.00% bibliografía, p:0.0000). La proporción de hemocultivos contaminados se redujo a la mitad, 3.08% vs 1.51%, p: 0.001. Se realizó una encuesta anónima pre y post intervención logrando mejoras en la técnica de toma de hemocultivos. Conclusión. La implementación del bundle propio para la extracción de hemocultivos, permitió reducir la proporción de contaminación a la mitad. El análisis de la encuesta nos permitió identificar oportunidades de mejora en la técnica de recolección de muestra de hemocultivos


Introduction: Contamination of blood cultures is very common in hospital care settings and results in the administration of unnecessary antibiotics and prolongs hospitalization. Main goal: Apply a bundle to reduce the rate of contamination of blood cultures. Secondary objective: Conduct an anonymous survey to detect opportunities for improvement in the blood culture extraction technique. Methodology: Study design: Quasi-experimental study that evaluated the proportion of blood culture contamination before and after implementing its own bundle. The baseline proportion of blood culture contamination was determined (Jan-July 2022), the intervention was performed (August 2022) and the post-intervention contamination proportion was established (September-April 2023). Intervention: The structure, procedure and knowledge of the staff was analyzed through an own survey to detect areas for improvement. Laboratory technicians were trained on the sample collection procedure through a simulation using an artificial arm. A bundle of six measures was designed: (hand hygiene with alcohol gel, use of common gloves and sterile gloves during extraction, antisepsis with alcoholic chlorhexidine gluconate, marking of the blood culture bottle up to the filling level, disinfection of the bottle cap). blood culture bottle with 70% alcohol, safety-lok kit with vacuum extraction system). The procedure was adapted and staff trained. Statistic analysis: The proportion of contaminated blood cultures between the pre and post periods was analyzed using Chi2 and the relationship between the proportion of the pre and post period vs the literature (3.00% acceptable contamination) using Z test for a proportion. P<0.05 was considered statistically significant. Stata 8 software was used.Results: A total of 3,965 blood cultures were analyzed during the study. Of these, 1,978 correspond to the pre-intervention period and 1,987 correspond to the post-intervention period. During the pre-intervention, 61 contaminated blood cultures were detected (3.08%) while in the post-intervention stage there were 30 contaminated blood cultures (1.51%). The proportion of contaminated blood cultures was reduced by half, 3.08% vs 1.51%, p: 0.001. An anonymous survey was carried out pre and post intervention, achieving improvements in the technique of taking blood cultures. Conclusion: The implementation of the own bundle for the extraction of blood cultures allowed the contamination rate to be reduced by ha


Assuntos
Humanos , Masculino , Feminino , Coleta de Amostras Sanguíneas/métodos , Hemocultura/métodos , Hemocultura/estatística & dados numéricos
8.
Scand J Clin Lab Invest ; 84(1): 62-67, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38451167

RESUMO

Glucose measurement plays a central role in the diagnosis of gestational diabetes mellitus (GDM). Because of earlier reports of overestimation of glucose in the widely used tubes containing granulated glycolysis inhibitor, the study assessed the performance of fast-clotting serum tubes as an alternative sample for the measurement of glucose. Glucose concentration in fast-clotting serum was compared to lithium-heparin plasma placed in an ice-water slurry after sample collection and glucose stability at room-temperature was studied. Blood samples from 30 volunteers were drawn in four different types of tubes (serum separator tubes, fast-clotting serum tubes, lithium-heparin tubes and sodium fluoride, EDTA and a citrate buffer (NaF-EDTA-citrate) tubes, all from Greiner Bio-One). Lithium-heparin tubes were placed in an ice-water slurry until centrifugation in accordance with international recommendations and centrifuged within 10 min. After centrifugation, glucose was measured in all tubes (timepoint T0) and after 24, 48, 72, 96 and 120 h of storage at 20-22 °C. NaF-EDTA-citrate plasma showed significant overestimation of glucose concentration by 4.7% compared to lithium-heparin plasma; fast-clotting serum showed glucose concentrations clinically equivalent to lithium-heparin plasma. In fast-clotting serum tubes, mean bias between glucose concentration after 24, 48, 72, 96 and 120 h and T0 was less than 2.4%. All individual differences compared to T0 were less than 6.5%. The results fulfill the acceptance criteria for sample stability based on biological variation. Fast-clotting serum tubes can be an alternative for the measurement of glucose in diagnosis and management of GDM and diabetes mellitus, especially when prolonged transportation is necessary.


Assuntos
Diabetes Gestacional , Heparina , Gravidez , Feminino , Humanos , Glucose , Ácido Cítrico/farmacologia , Ácido Edético , Lítio , Glicemia , Temperatura , Gelo , Citratos , Coleta de Amostras Sanguíneas/métodos , Fluoreto de Sódio/farmacologia , Diabetes Gestacional/diagnóstico , Centrifugação
9.
Clin Chim Acta ; 557: 117890, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38537673

RESUMO

BACKGROUND: Volumetric Absorptive Microsampling (VAMS) is emerging as a valuable technique in the collection of dried biological specimens, offering a potential alternative to traditional sampling methods. The objective of this study was to assess the suitability of 30 µL VAMS for the measurement of endogenous steroid hormones. METHODS: A novel LC-MS/MS method was developed for the quantification of 18 analytes in VAMS samples, including main endogenous free steroids and phase II metabolites of androgens. The method underwent validation in accordance with ISO/IEC 17025:2017 and World Anti-Doping Agency (WADA) requirements. Subsequently, it was applied to authentic VAMS samples obtained from 20 healthy volunteers to assess the stability of target analytes under varying storage conditions. RESULTS: The validation protocol assessed method's selectivity, matrix effect, extraction recovery, quantitative performance, carry-over and robustness. The analysis of authentic samples demonstrated the satisfactory stability of monitored steroids in VAMS stored at room temperature, 4 °C, -20 °C and -80 °C for up to 100 days and subjected to up to 3 freezing-thawing cycles. CONCLUSIONS: The validated LC-MS/MS method demonstrated its suitability for the measurement of steroids in dried blood VAMS. The observed stability of steroidal compounds suggests promising prospects for future applications of VAMS, both in anti-doping contexts and clinical research.


Assuntos
Doping nos Esportes , 60705 , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Coleta de Amostras Sanguíneas/métodos , Androgênios , Esteroides , Teste em Amostras de Sangue Seco/métodos
10.
Med Eng Phys ; 125: 104121, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508800

RESUMO

We are developing an automatic fingertip-blood-sampling system to reduce the burden on trained medical personnel. For this system to withdraw a consistent volume of sampled blood for blood tests, we developed a mechanism for our system to select and puncture the vicinity of a large blood vessel from the blood-vessel image of an individual's fingertip. We call this mechanism the fingertip-vessel-puncture mechanism. From the results of an experiment in which the fingertips of 20 individuals (men and women in their 20 s to 60 s) were manually punctured at near and far locations from the blood vessel selected with our mechanism, the following conclusions were obtained. The fingertip-vessel-puncture mechanism tends to increase the volume of sampled blood, thus is effective in sampling more than 650 µL of blood for automatic blood analyzers. It was also found that it is more effective in increasing the volume of sampled blood in the men and those who were younger.


Assuntos
Coleta de Amostras Sanguíneas , Dedos , Masculino , Humanos , Feminino , Coleta de Amostras Sanguíneas/métodos
11.
J Pharm Biomed Anal ; 242: 116065, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401349

RESUMO

Volumetric absorptive microsampling (VAMS) is increasingly proposed as a clinically reliable therapeutic drug monitoring (TDM) sampling methodology. The study aimed to establish the reliability and real-life feasibility of patient self-collected capillary VAMS for TDM of antiseizure medication (ASMs), using plasma ASMs concentrations from venous blood as a reference standard. Nurses collected venous and capillary blood samples using VAMS. Afterward, persons with epilepsy (PWE) performed VAMS sampling by themselves. All samples were analyzed by UHPLC-MS/MS. We performed a cross-validation study, comparing ASMs concentrations obtained by VAMS nurses and patients' self-collected versus plasma through Bland-Altman analysis and Passing-Bablok regression. We enrolled 301 PWE (M: F 42.5%:57.5%; mean age 44±16 years), treated with 13 ASMs, providing a total of 464 measurements. Statistical analysis comparing VAMS self-collected versus plasma ASMs concentrations showed a bias close to zero and slope and intercept values indicating a good agreement for CBZ, LCS, LEV, LTG, OXC, PB, and PHT, while a systematic difference between the two methods was found for VPA, PMP, TPM and ZNS. This is the first study showing the reliability and feasibility of the real-world application of PWE self-collected VAMS for most of the ASMs considered, giving a promising basis for at-home VAMS applications.


Assuntos
Epilepsia , Espectrometria de Massas em Tandem , Humanos , Adulto , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem/métodos , Monitoramento de Medicamentos/métodos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Coleta de Amostras Sanguíneas/métodos , Teste em Amostras de Sangue Seco/métodos , Epilepsia/tratamento farmacológico
13.
BMC Pediatr ; 24(1): 110, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350923

RESUMO

INTRODUCTION: Due to medical procedures, preterm infants are at high risk for side effects of pain. In this regard, heel lancing for capillary blood sampling is a common painful procedure. The present study was conducted to assess the effectiveness of a simulated intrauterine sound on behavioral and physiological indices of pain due to heel-prick blood sampling in preterm infants. METHODS: A double­blind randomized clinical trial (RCT) was conducted. The data were collected from September 23 to December 22, 2019. We measured the effect of a simulated intrauterine sound on changes in the behavioral and physiological parameters of pain (heart rate, SPO2) caused by heel lance that was measured 5 min before the intervention, during the sampling, and 5 min after the procedure. We measured behavioral pain by video recording the infants' faces and then the scoring neonatal infant pain scale (NIPS). Heart rate and SPO2 were measured using a pulse oximeter device. The data were analyzed using analysis of variance (ANOVA) and independent t­test in SPSS software version 20.0. RESULTS: Eighty infants were randomized (40 in each group). Mean scores NIPS during and after intervention were in the intervention group (3.55 ± 0.84, 95% CI: 3.30-3.80(, and (1.15 ± 0.84, 95%: 0.95-1.35) and in the control group (5.57 ± 0.95, 95% CI:5.30-5.85) and (3.00 ± 0.98) respectively. There were significant differences in scores of NIPS between the two study groups during (p < 0.001) and five min after heel lancing (p < 0.001). Mean scores of heart rate in the three phases of before, during, and five min after the intervention were respectively in the intervention group (127.57 ± 4.45, 95% CI:126.27-128.99), (131.07 ± 6.54, 95% CI:129.20-133.22), (128.45 ± 5.15, 95% CI:127.02-130.07) and in the control group (128.67 ± 4.57, 95% CI:127.32-130.07), (136.07 ± 7.24, 95% CI:133.90-138.37), and (132.42 ± 6.47, 95% CI:130.37-134.49). There were significant differences in heart rate between the intervention and the control group during (p = 0.002) and five min after the heel lance (p = 0.003). Mean scores of SPO2 in the three phases of baseline, during, and five min after the intervention were respectively in the intervention group (96.72 ± 0.93, 95% CI:96.42-97.00), (91.47 ± 1.46, 95% CI:91.05-91.92), (94.17 ± 1.03, 95% CI:93.22-94.00) and in the control group (96.6 ± 0.84, 95% CI:96.35-96.85), (91.5 ± 1.24, 95% CI:91.12-91.87), and (93.60 ± 1.27, 95% CI:93.85-94.50). CONCLUSION: This study showed that the simulated intrauterine sound reduces the behavioral pain and heart rate in the intervention group during and after heel lance. These results suggest using the method during the painful heel lancing to reduce pain parameters in preterm infants.


Assuntos
Coleta de Amostras Sanguíneas , Recém-Nascido Prematuro , Recém-Nascido , Humanos , Coleta de Amostras Sanguíneas/efeitos adversos , Coleta de Amostras Sanguíneas/métodos , Dor/etiologia , Dor/prevenção & controle , Punções/efeitos adversos , Manejo da Dor/efeitos adversos , Manejo da Dor/métodos
14.
Vet Med Sci ; 10(2): e1368, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38356378

RESUMO

BACKGROUND: Delays between blood collection and analysis are inevitable, and samples are always stored in the refrigerator. The current study aimed to evaluate the stability of serum total cholesterol (TC), triglycerides (TG), total protein (TP), albumin and urea (URA) in horses and oxen after storage at -20°C. METHODS: Sera from apparently healthy 20 male horses and 20 oxen were obtained and aliquots of serum were divided into 3 portions. The first tube was used for baseline (T0) measurement of analyte values, whereas the other two tubes, T1 and T2, were stored at -20°C for 1 and 2 months, respectively, and analyte measurement was done. RESULTS: Results showed that the stability of TP (g/dL), URA (mg/dL) and TC (mg/dL) in oxen was statistically significant (p < 0.05). In horses, the stability of URA (mg/dL), TP (g/dL) and TG (mg/dL) were also statistically significant (p < 0.05). Additionally, URA and TC in oxen exceed TEa following measurement at T2 and TG in horses following measurement at T1 and T2. CONCLUSION: Laboratories should consider the storage temperature and time for specific analytes among animals. Therefore, stability studies at various storage temperatures and times are recommended to fully validate the stability of the analytes.


Assuntos
Coleta de Amostras Sanguíneas , Soro , Masculino , Cavalos , Animais , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/veterinária , Triglicerídeos , Fatores de Tempo , Temperatura
15.
J Pharm Biomed Anal ; 241: 115993, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38306865

RESUMO

Serial blood sampling from one animal is useful to understand relationship between pharmacokinetics (PK) and pharmacological or toxicological events in individual animals. To assess its feasibility in mice, two therapeutic antibodies were used to evaluate impacts by different blood sampling methods, sampling sites, and assay platforms on PK. Denosumab and Panitumumab were intravenously administered to mice and only 0.05 mL of blood sample per point was collected from jugular vein or tail vein. Blood samples were collected serially from a mouse or collected by traditional composite sampling from each mouse. Plasma concentrations of the two drugs were assayed by a generic ligand binding assay using Gyrolab or by a generic ultra-performance liquid chromatography with tandem mass spectrometry. The two assay platforms showed acceptable accuracy and precision and gave comparable PK parameters of the drugs, suggesting that both assays were successfully applied to the PK assessments. Comparable results in the PK profiles were noted between serial and composite blood samplings and differences in the two sampling sites did not impact PK. These findings suggest that microsampling combined with generic assays is useful to assess PK profiles of therapeutic antibodies in mice.


Assuntos
60705 , Espectrometria de Massas em Tandem , Camundongos , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Coleta de Amostras Sanguíneas/métodos , Teste em Amostras de Sangue Seco
16.
Hematology ; 29(1): 2314871, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38346146

RESUMO

OBJECTIVE: To investigate the influence of the dead space in disposable blood sampling needle on activated partial thromboplastin time (APTT), FVIII level and pharmacokinetic (PK) profiles in children with hemophilia. METHODS: Children (<18 years) with severe hemophilia A were enrolled. After three days' washout-period, blood samples were collected at pre-dose, 1 h, 3 h, 9 h, 24 h and 48 h post-infusion. At each timepoint, two 2 mL vacuum tubes with 3.2% trisodium citrate were used. The first tube was signed as 'non-standard' (NS) and the second tube was signed as 'standard' (S). FVIII activities were evaluated by one-stage assay. WAPPS-Hemo was used to generate PK profiles like half-life time (t1/2), clearance (CL), trough level and time to 1, 2 and 5IU/dL after a dose of 50 ± 10IU/dL. The FVIII activities at 9 h and 24 h post-infusion were put into WAPPS and thus brought four combinations by true or biased FVIII level that used. RESULT: Compared with standard-collected blood samples, prolonged APTT results (P-values < 0.01) and decreased FVIII activity (P-values < 0.05) were revealed in those non-standard blood samples. The corresponding bias was in positive relation to both APTT-S (r = 0.44, P < 0.0001) and FVIII-S level(r = 0.68, P < 0.001). The FVIII bias percentage got larger as FVIII-S level reduced (r = -0.24, P < 0.01). During the four combinations of FVIII activity at 9 h and 24 h, statistically longer t1/2, lower CL and longer time to 1, 2 or 5IU/dL were observed in 9H-S&24H-S group and 9H-NS&24H-S group. CONCLUSION: While using vacuum tubes for clotting indicators and PK profiles, the dead space of blood sampling needle should be eliminated in advance.


Assuntos
Coleta de Amostras Sanguíneas , Fator VIII , Hemofilia A , Tempo de Tromboplastina Parcial , Criança , Humanos , Coagulação Sanguínea , Fator VIII/farmacocinética , Meia-Vida , Hemofilia A/sangue , Hemofilia A/diagnóstico , Agulhas , Tempo de Tromboplastina Parcial/normas , Coleta de Amostras Sanguíneas/normas
17.
Bioanalysis ; 16(4): 203-217, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38226838

RESUMO

Background: Clinical dosage of toxic and essential elements in blood is well established and the collection method is still by venipuncture. This method has drawbacks and is not suited for everyone. Volumetric absorptive microsampling (VAMS) has been shown to have advantages over venipuncture. Materials & methods: Using inductively coupled plasma tandem mass spectrometry, a method for quantifying elements in whole blood sampled on VAMS was developed/validated. Method's performance was assessed by comparison with whole blood results. Results: Validation and performance assessment tests tend to show that most of the targeted elements provides accurate and reproducible results comparing to a method of reference. Conclusion: Overall, VAMS presents good preliminary results to eventually become an alternative to venipuncture for blood sampling for some trace elements analysis purposes.


Assuntos
Espectrometria de Massas em Tandem , Oligoelementos , Espectrometria de Massas em Tandem/métodos , Coleta de Amostras Sanguíneas/métodos , Manejo de Espécimes/métodos , Teste em Amostras de Sangue Seco/métodos
18.
BMC Res Notes ; 17(1): 16, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38178164

RESUMO

OBJECTIVE: The quality of dried blood spot (DBS) specimens impacts newborn screening (NBS) results, hence proper training is crucial for DBS specimen collection. To address this, a training module for Allied Health Professionals (AHPs) and nurses was created on Moodle, a virtual learning environment (VLE). The purpose of this research was to determine the feasibility and effectiveness of this module. METHODOLOGY: Participants were trained on-site (March to December 2019), through online training sessions (January to June 2020), and the two training strategies were compared. Data analysis included the total number of participants, cost-effectiveness, trainer engagement, and the number of unacceptable samples collected by nurses/AHPs trained by the two strategies. RESULTS: A total of 55 nurses/AHPs were trained on-site, while 79 nurses/AHPs completed the online module and received certificates through online VLE-based training. The trainer engagement and cost were more for onsite training. After online training, the specimen rejection rate was reduced from 0.84% (44 rejected out of 5220 total specimens collected) to 0.38% (15/3920). CONCLUSIONS: This study shows that using VLE-based DBS specimen collection training is feasible and effective for training nurses and AHPs.


Assuntos
Educação a Distância , Recém-Nascido , Humanos , Estudos Transversais , Manejo de Espécimes , Coleta de Amostras Sanguíneas
19.
J Infus Nurs ; 47(1): 36-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211613

RESUMO

PowerGlide Pro™ Midline Catheters, manufactured by Becton Dickinson, are marketed as capable of obtaining blood specimens. However, there is insufficient research to validate the laboratory results collected from these specialty catheters. The purpose of this research study was to determine whether blood samples obtained via venipuncture and samples obtained directly from a midline catheter are clinically equivalent. A qualitative study was completed per recommendations published in Clinical and Laboratory Standards Institute (CLSI) standards EP-05-A3 to determine whether the 2 modalities are clinically equivalent. A 12-point correlation study was performed, comparing blood results from phlebotomy venipuncture and midline catheter blood draws for 20 successful participants. Results were compared with an EP Evaluator. Report interpretation was completed using the 2-instrument comparison module to determine whether the 2 methods were clinically equivalent. All correlated specimens resulted within the medically acceptable total allowable error, proving the 2 methods clinically equivalent. The study concluded that blood draws from midline catheters are clinically equivalent to venipuncture and are an acceptable form of specimen collection for laboratory studies.


Assuntos
Coleta de Amostras Sanguíneas , Flebotomia , Humanos , Flebotomia/métodos , Coleta de Amostras Sanguíneas/métodos , Cateteres , Cateteres de Demora
20.
Anal Chem ; 96(5): 1993-1999, 2024 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-38266026

RESUMO

The accurate and efficient measurement of white blood cell (WBC) counts is vital for monitoring general patient health and can aid in the diagnosis of a range of possible infections or diseases. Even with their importance universally acknowledged, access to WBC counts is largely limited to those with access to phlebotomists and centralized clinical laboratories, which house the instruments that perform the tests. As a result, large populations of people (e.g., those that are home-bound or live in remote locations) lack facile access to testing. Dried blood spot (DBS) cards are often used to bridge these gaps in access to testing by offering the ability to collect blood at home for ambient shipping to laboratories. However, it is well understood that these cards, which are prepared from cellulose cardstocks without further modification, suffer from variabilities in accuracy and precision due to uncontrolled sample spreading and hematocrit effects, which have hindered their use to determine WBC counts. In this paper, we present a method to obtain an accurate WBC count using a patterned dried blood spot (pDBS) card, which comprises collection zones that meter volumes of dried blood. Using an input volume of 75 µL of whole blood, we demonstrate that, unlike the gold standard DBS card (Whatman 903), our pDBS design allows for the collection of replicate zones containing a reproducible, average volume of dried blood (12.1 µL, 7.8% CV) over the range of hematocrits from 25 to 55%. We then used qPCR to quantify the 18S rRNA gene to determine WBC counts from the volumes of blood that are metered in pDBS zones. We observe that WBC counts generated from our method are comparable to those measured with a HemoCue point-of-care WBC analyzer. Our approach to using pDBS cards as a blood collection device has the potential to support at-home sampling and other patient populations that need WBC counts but lack access to clinical facilities.


Assuntos
Coleta de Amostras Sanguíneas , Teste em Amostras de Sangue Seco , Humanos , Hematócrito , Teste em Amostras de Sangue Seco/métodos , Contagem de Leucócitos , Celulose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA